In 1927, riding the ferry to work, Harold Black at Bell Labs sketched the negative-feedback amplifier on a newspaper. Long-distance telephone calls needed amplifiers built from unreliable vacuum tubes; feeding part of the output back made their gain precise, dependent on the sensor rather than on the unreliable part.
We will close the feedback loop and finish with precision from the sensor.
Step 1: Feedback loops
A feedback controller measures the output, compares the measurement with the reference r it is meant to follow, and acts on the difference. Call the plant's gain G and the sensor's gain H. The controller sees the error e = r − Hy, the reference minus the measurement, and the plant turns it into y = Ge. Substituting, y = G(r − Hy), so y(1 + GH) = Gr and
The product GH, the gain a signal picks up going once around the loop, is the loop gain. With G = 40 and H = 0.2 the loop gain is 8, and the closed-loop gain is 40 ÷ 9 ≈ 4.44.
Step 2: Precision from the sensor
When the loop gain is large, the 1 in the denominator hardly matters, and G ÷ (1 + GH) ≈ G ÷ GH = 1/H: the closed-loop gain is set by the sensor, not by the plant. Take G = 2,000 and H = 0.05, so GH = 100: the gain is 2,000 ÷ 101 ≈ 19.8, close to 1/H = 20. If the plant gain halves to 1,000, the gain becomes 1,000 ÷ 51 ≈ 19.6, a change of about 1%. That is why op-amp circuits built from wildly variable transistors have precise gains set by two resistors.
To hit an exact closed-loop gain T, solve G ÷ (1 + GH) = T for the sensor gain: H = (G/T − 1) ÷ G. With G = 100 and T = 5, H = (20 − 1) ÷ 100 = 0.19; check: 100 ÷ (1 + 19) = 5.